Classification

Recommended Cases

China Telecom - Heptafluoropropane Project

China Telecom - Heptafluoropropane Project

China Mobile - Heptafluoropropane Project

China Mobile - Heptafluoropropane Project

China Southern Power Grid - Heptafluoropropane Project

China Southern Power Grid - Heptafluoropropane Project

Contact us

Guangzhou Rijian Firefighting Equipment Co.,Ltd.

E-mail:gzrjfire@163.com

Web:www.rjfire.com

Rijian. Trademark

Rijian Fire Protection. Website

Add:Huangpu District double sand industrial zone, Guangzhou, Guangdong Province, Fu Rd 32

 

Fire hydrant box

The fire hydrant box refers to a box used to store fire hydrants, which is used to extinguish fire in the event of a fire. It should be equipped with water hoses, water guns, etc. The installation methods include surface mounting, concealed mounting, and semi concealed mounting

More

Fire audible and visual alarm SG-993

The internationally renowned agreed CPU is adopted, with fast computing speed and reliable performance. Polarity signal 2-bus, easy to apply 1 wiring channel to avoid wiring errors. The acoustic and/or optical alarms are freely set to adapt to different working environments. FIRE To use a super shell red LED as a light source, displaying wakefulness, long life, and low power consumption. Mountain ESD electrostatic protection grade: 8000V, with stronger anti-interference ability. The SG-993K fire audible and visual alarm sends control signals through the K7-953 output module.

More

Gas release alarm QM-ZSD-02

Non polarity signal two bus facilitates construction wiring and avoids wiring errors. The mountain adopts MCU to control flash and acoustic alarm drive, which is stable and reliable. Before the gas is released, the mountain sends out a light indication, and the indicator panel has a Chinese warning sign. Tiku on-site personnel are not allowed to enter the gas fire protection zone. Connect to B-QBL-QM300V4 or JB-QBL-QM210 gas fire extinguishing control panel for supporting use.

More

Manual automatic switching box QM-MA-968

It is installed outside the entrance and exit of the gas fire protection area, and the high brightness LED lamp displays the working status. The OM-MQ-966 manual/automatic changeover disk is designed with a dedicated key to avoid incorrect operation. JB-QBL-QM300V4 or JB-OBL-OM210 body fire extinguishing control panel shall be used together.

More

Emergency start/stop button QM-AN-967

▲ When a fire occurs and it is necessary to start the gas fire extinguishing system, open the button protective cover and press the start button to provide a start control signal, while the start indicator light is lit. ▲ When it is confirmed that the fire has been controlled or the fire alarm is a false alarm, and it is still in the delay stage, you can immediately press the stop button to interrupt the deflation delay, while the stop indicator light is on, and the start indicator light is off.

More

Point type temperature sensitive fire detector

The internationally renowned agreed CPU is adopted, with stable and reliable performance and strong anti-interference ability. The temperature sensing element is made of epoxy resin, providing better insulation. There are two types of constant temperature and differential temperature, with a wide range of applications. The alarm sensitivity of the detector is adjustable at three levels to adapt to different environmental requirements. The unique degree compensation algorithm design can improve the response ability under different heating conditions. Patented 15 second extreme speed alarm.

More

Point type photoelectric smoke fire detector

The internationally renowned agreed CPU and patented design of a backward labyrinth can accurately detect famous types of fire smoke. The detector's alarm sensitivity is adjustable at three levels to adapt to different environmental requirements. It has a patented fire alarm active reporting system that provides an extremely fast alarm within 1.5 seconds.

More

Gas fire extinguishing controller

▲ Adopt non polarity signal two bus. It can automatically identify the duplicate address code of the terminal equipment in the loop and eliminate the crosstalk startup of the fire extinguishing zone. ▲ The industry's exclusive fire alarm and fault signal active upload technology allows the controller to respond in only 2 seconds. ▲ You can use a USB flash disk for data backup and recovery. ▲ Compatible with 9116 series fire detectors and modules, and can be networked with 9116 series controllers to upload signals and receive reset commands issued by the controller. ▲ Each fire extinguishing zone has an independent sound and light start/stop button and a manual/automatic changeover switch, which can independently set automatic venting conditions and automatic venting condition delay time. ▲ Applicable places: Used in places where electrical fires, solid surface fires, liquid fires, and gas fires that can cut off the gas source may occur. Used for connecting cabinet type and pipe network heptafluoropropane fire extinguishing devices, mixed gas fire extinguishing device IG541, and high and low pressure carbon dioxide fire extinguishing devices.

More

Intelligent/micro fire station

Suitable for storing fire-fighting clothing, helmets, boots, axes, shovels, and other fire-fighting accessories. Miniature fire stations that assist in extinguishing fire in important places such as large buildings, factories, warehouses, office buildings, living quarters, conference halls, exhibition halls, and business districts.

More

Fire extinguisher box

Fire extinguisher box is a box specially used for long-term fixed storage of portable fire extinguishers. According to the placement type, it can be divided into two types: floor mounted and wall mounted. According to the opening method, it can be divided into two types: open door type and flip type. The fire extinguisher box shall be made of metal materials such as thin steel plate and aluminum alloy.

More

Foam hydrant box

The foam fire hydrant box can spray low expansion air foam to put out Class B fires caused by petroleum products, as well as spot fires caused by general solid materials such as wood and counterfeit goods; Or spray only pressurized water to extinguish Class A fires.

More

Portable - wheeled fire extinguisher

Portable dry powder fire extinguishers are suitable for initial fires of flammable, combustible liquids, gases, and electrified equipment, as well as for initial fires of solid substances. But none of them can put out metal burning fires. Portable carbon dioxide fire extinguishers can be used on Class B, C, and E fires. The function is to expel air and extinguish the fire without oxygen. Wheeled dry powder fire extinguishers are suitable for extinguishing incipient fires of combustible materials, liquids, gases, and live equipment. It is widely used in factories, warehouses, ships, gas stations, power distribution rooms, vehicles, etc.

More

Fire hydrant

Fire hydrants are usually used in conjunction with fire hydrant connectors, water hoses, and water guns to extinguish fires.

More

Automatic gas fire extinguishing system

Automatic gas fire extinguishing system

More

Portable carbon dioxide fire extinguishers

Carbon dioxide fire extinguishers Carbon dioxide (CO2) can be used on Class B, C, and E fires. The function is to expel air and extinguish the fire without oxygen. Because carbon dioxide is a gas that does not remain, it can be used in electric fires to avoid damaging equipment. "It is feasible to use carbon dioxide on Class A fires, but it must be used for a long time. Portable fire extinguishers cannot provide sufficient dose. The top of the nozzle of carbon dioxide fire extinguishers is usually a cylindrical shape.". Due to the extremely low temperature of carbon dioxide stored in fire extinguishers, care should be taken to avoid contact during use to avoid frostbite. Because using carbon dioxide to extinguish a fire can reduce the amount of oxygen in the fire site and combusting items, using carbon dioxide in an environment where the air is not circulating can affect breathing and is not suitable for long-term use. You must leave the scene as soon as possible after use.

More
< 12 >