Gas fire extinguishing

Gas fire extinguishing

Gas Fire Extinguishing

Related Cases

图片名称

China Telecom - Heptafluoropropane Project

图片名称

China Mobile - Heptafluoropropane Project

图片名称

China Southern Power Grid - Heptafluoropropane Project

Contact us

Guangzhou Rijian Firefighting Equipment Co.,Ltd.

E-mail:gzrjfire@163.com

Web:www.rjfire.com

Rijian. Trademark

Rijian Fire Protection. Website

Add:Huangpu District double sand industrial zone, Guangzhou, Guangdong Province, Fu Rd 32

 

Fire audible and visual alarm SG-993

The internationally renowned agreed CPU is adopted, with fast computing speed and reliable performance. Polarity signal 2-bus, easy to apply 1 wiring channel to avoid wiring errors. The acoustic and/or optical alarms are freely set to adapt to different working environments. FIRE To use a super shell red LED as a light source, displaying wakefulness, long life, and low power consumption. Mountain ESD electrostatic protection grade: 8000V, with stronger anti-interference ability. The SG-993K fire audible and visual alarm sends control signals through the K7-953 output module.

More

Gas release alarm QM-ZSD-02

Non polarity signal two bus facilitates construction wiring and avoids wiring errors. The mountain adopts MCU to control flash and acoustic alarm drive, which is stable and reliable. Before the gas is released, the mountain sends out a light indication, and the indicator panel has a Chinese warning sign. Tiku on-site personnel are not allowed to enter the gas fire protection zone. Connect to B-QBL-QM300V4 or JB-QBL-QM210 gas fire extinguishing control panel for supporting use.

More

Manual automatic switching box QM-MA-968

It is installed outside the entrance and exit of the gas fire protection area, and the high brightness LED lamp displays the working status. The OM-MQ-966 manual/automatic changeover disk is designed with a dedicated key to avoid incorrect operation. JB-QBL-QM300V4 or JB-OBL-OM210 body fire extinguishing control panel shall be used together.

More

Emergency start/stop button QM-AN-967

▲ When a fire occurs and it is necessary to start the gas fire extinguishing system, open the button protective cover and press the start button to provide a start control signal, while the start indicator light is lit. ▲ When it is confirmed that the fire has been controlled or the fire alarm is a false alarm, and it is still in the delay stage, you can immediately press the stop button to interrupt the deflation delay, while the stop indicator light is on, and the start indicator light is off.

More

Point type temperature sensitive fire detector

The internationally renowned agreed CPU is adopted, with stable and reliable performance and strong anti-interference ability. The temperature sensing element is made of epoxy resin, providing better insulation. There are two types of constant temperature and differential temperature, with a wide range of applications. The alarm sensitivity of the detector is adjustable at three levels to adapt to different environmental requirements. The unique degree compensation algorithm design can improve the response ability under different heating conditions. Patented 15 second extreme speed alarm.

More

Point type photoelectric smoke fire detector

The internationally renowned agreed CPU and patented design of a backward labyrinth can accurately detect famous types of fire smoke. The detector's alarm sensitivity is adjustable at three levels to adapt to different environmental requirements. It has a patented fire alarm active reporting system that provides an extremely fast alarm within 1.5 seconds.

More

Gas fire extinguishing controller

▲ Adopt non polarity signal two bus. It can automatically identify the duplicate address code of the terminal equipment in the loop and eliminate the crosstalk startup of the fire extinguishing zone. ▲ The industry's exclusive fire alarm and fault signal active upload technology allows the controller to respond in only 2 seconds. ▲ You can use a USB flash disk for data backup and recovery. ▲ Compatible with 9116 series fire detectors and modules, and can be networked with 9116 series controllers to upload signals and receive reset commands issued by the controller. ▲ Each fire extinguishing zone has an independent sound and light start/stop button and a manual/automatic changeover switch, which can independently set automatic venting conditions and automatic venting condition delay time. ▲ Applicable places: Used in places where electrical fires, solid surface fires, liquid fires, and gas fires that can cut off the gas source may occur. Used for connecting cabinet type and pipe network heptafluoropropane fire extinguishing devices, mixed gas fire extinguishing device IG541, and high and low pressure carbon dioxide fire extinguishing devices.

More

Automatic gas fire extinguishing system

Automatic gas fire extinguishing system

More