Hello, welcome to the official website of Rijian Firefighting

产品中心 产品中心
/
/
/
Heptafluoropropane gas fire extinguishing system device

CLASSIFICATION

All categories
Number of views:
1000

Heptafluoropropane gas fire extinguishing system device

First, product description The device is designed with advanced design, reliable performance, simple operation and good environmental protection. Heptafluoropropane gas does not contain chlorine or bromine and has no destructive effect on the atmospheric ozone layer. At present, it is used to replace 1301 and 1211 harmful to the environment as the raw material of fire extinguishing agent. It has high fire extinguishing efficiency and non-toxic. It is suitable for protected areas with permanent staff. QMH4. Type 2 heptafluoropropane fire extinguishing system adopts high-pressure storage, automatic and manual operation release mode. When the ambient temperature is lower than 50 ℃, the working pressure of the system shall not exceed 5.3mpa. GQQ2. Type 5 cabinet heptafluoropropane fire extinguishing device, and the working pressure of the system shall not exceed 4.2mpa. Second, product basis Heptafluoropropane fire extinguishing system is a modern intelligent automatic fire extinguishing device integrating gas fire extinguishing, automatic (manual) control and fire detection. The design and manufacture of the system comply with China's gb50370-2005 code for design of gas fire extinguishing systems (2006 Edition), gb25972-2010 general technical conditions for components of gas fire extinguishing systems Gb50263-2007 code for construction and acceptance of gas fire extinguishing system. Third, application scope The system is applicable to heptafluoropropane fire extinguishing system set in new construction, reconstruction and expansion projects and production and storage devices. Widely used to protect: 1. Computer room, communication room, SPC exchange room and other computer rooms; 2. Generator room, power transformation and distribution room, power plant, power station, precision instrument room Laboratory, coating equipment room, oil depot, chemical and inflammable warehouse; 3. Archives, libraries, reference rooms, art galleries, museums, cultural relics museums, bank vaults and other places; 4. Financial institutions, government agencies, television broadcasting centers, hospitals, banks, buildings, factories and other valuable equipment rooms that cannot be drenched with water. It is suitable for extinguishing electrical fire, liquid fire, fusible solid fire, solid surface fire and gas fire that can cut off the gas source before extinguishing. Fourth, product maintenance 1. Heptafluoropropane liquid storage bottle shall check the weight of extinguishing agent once a month. If the net weight of extinguishing agent is reduced by 5% or more, the leakage cause shall be found out, eliminated and refilled. 2. Check the weighing device of each liquid storage bottle every month for corrosion or damage. In case of corrosion, looseness and reduced sensitivity, it shall be retested and qualified or replaced before reuse.   3. Check the installation and fixation status of flexible connecting pipe and other piping systems every year; Check its appearance for corrosion or damage. If aging is found, it should be replaced before reuse.
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
0
Services line: 400-6148-119
WeChat official account
1
Detailed
Parameters

First, product description
The device is designed with advanced design, reliable performance, simple operation and good environmental protection. Heptafluoropropane gas does not contain chlorine or bromine and has no destructive effect on the atmospheric ozone layer. At present, it is used to replace 1301 and 1211 harmful to the environment as the raw material of fire extinguishing agent. It has high fire extinguishing efficiency and non-toxic. It is suitable for protected areas with permanent staff. QMH4. Type 2 heptafluoropropane fire extinguishing system adopts high-pressure storage, automatic and manual operation release mode. When the ambient temperature is lower than 50 ℃, the working pressure of the system shall not exceed 5.3mpa. GQQ2. Type 5 cabinet heptafluoropropane fire extinguishing device, and the working pressure of the system shall not exceed 4.2mpa.
Second, product basis
Heptafluoropropane fire extinguishing system is a modern intelligent automatic fire extinguishing device integrating gas fire extinguishing, automatic (manual) control and fire detection. The design and manufacture of the system comply with China's gb50370-2005 code for design of gas fire extinguishing systems (2006 Edition), gb25972-2010 general technical conditions for components of gas fire extinguishing systems Gb50263-2007 code for construction and acceptance of gas fire extinguishing system.
Third, application scope
The system is applicable to heptafluoropropane fire extinguishing system set in new construction, reconstruction and expansion projects and production and storage devices. Widely used to protect:
1. Computer room, communication room, SPC exchange room and other computer rooms;
2. Generator room, power transformation and distribution room, power plant, power station, precision instrument room
Laboratory, coating equipment room, oil depot, chemical and inflammable warehouse;
3. Archives, libraries, reference rooms, art galleries, museums, cultural relics museums, bank vaults and other places;
4. Financial institutions, government agencies, television broadcasting centers, hospitals, banks, buildings, factories and other valuable equipment rooms that cannot be drenched with water. It is suitable for extinguishing electrical fire, liquid fire, fusible solid fire, solid surface fire and gas fire that can cut off the gas source before extinguishing.
Fourth, product maintenance
1. Heptafluoropropane liquid storage bottle shall check the weight of extinguishing agent once a month. If the net weight of extinguishing agent is reduced by 5% or more, the leakage cause shall be found out, eliminated and refilled.
2. Check the weighing device of each liquid storage bottle every month for corrosion or damage. In case of corrosion, looseness and reduced sensitivity, it shall be retested and qualified or replaced before reuse.  
3. Check the installation and fixation status of flexible connecting pipe and other piping systems every year; Check its appearance for corrosion or damage. If aging is found, it should be replaced before reuse.

Keyword:
Fire fighting
Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Related Products

 Anti foaming foam extinguishing agent 6% SAR -8 C
Anti foaming foam extinguishing agent 6% SAR -8 C
First, basic functions: Brief description: 6% S/AR type foam extinguishing agent is a kind of fire extinguishing agent with high solubility and high quality. It can mix 6 volumes with 94 volumes of fresh water to extinguish the fire of polar or solvent soluble fuels such as alcohols, ketones, esters, ethers and other flammable liquids. It can also be used to extinguish non-polar hydrocarbon and oil fire. It is a general foam extinguishing agent. 6% S/AR foam extinguishing agent is a kind of fire extinguishing agent containing special biopolymers. The foam quality produced by this polymer has better stability and heat resistance, fire resistance and sealing performance than ordinary foam. Second, characteristics 1。 The low power liquid-resistant foam has the smallest stirring energy. 2。 It can quickly overwhelm the flame quenching oil fire in a short time. 3。 Suitable for mixing with clean water. 3。 Standard foam proportioning mixer and other foaming devices are compatible. 4。 The 6% S/AR type anti foam foam extinguishing agent is versatile foam extinguishing agent, which can simplify the B fuel fires that are not known or mixed with oil and polar solvents in the fire field. 5。 The storage time is 2-3 years. Third, the physical and chemical properties of fire extinguishing agent Appearance - light yellow paste Specific gravity (20 ℃), g / cm 3-1.01-1.10 PH value (20 ℃) ---- 6-9.5 Anti freezing and melting performance -- no visible stratification and heterogeneous Fluidity ---- the flow is greater than the standard reference solution Foaming multiple ------- the deviation from the characteristic value shall not be greater than 1.0 , or not greater than the characteristic value 20% 25% liquid separation time, min -- the deviation from the characteristic value shall not be greater than 20% Fire extinguishing time (acetone), min -----------≤ 3 Anti burning time (acetone), min -----------≥ 10 Fire extinguishing time (120# solvent oil), min -- strong application ≤ 3, slow application ≤ 5 Anti burning time (120# solvent oil), min -- slow release ≥ 10 Freezing point, ℃------------------------------------------------------------------ Service temperature, ℃---------- freezing point + 5 ~ 40 Fourth, product application scope: The S/AR6% type anti foam foam extinguishing agent is mainly used to extinguish fire such as alcohols, esters, aldehydes, ethers, amines, organic acids, heterocyclic and other polar (or water-soluble) solvents. It can also fight non-polar hydrocarbon and oil fires. It is a general type foam extinguishing agent. It can be applied to large scale chemical industry, petrochemical industry, chemical fiber enterprise, and numerous small and medium-sized chemical plants, paint factories, alcohol factories, etc. Chemical products warehouse and other places. Its general performance can simplify the remediation of class B fuel fires that are unknown or mixed with oils and polar solvents.
 Cabinet heptafluoropropane gas fire extinguishing system
Cabinet heptafluoropropane gas fire extinguishing system
Product Name: cabinet heptafluoropropane gas fire extinguishing system Specification and model: GQQ40 / 70 / 90 / 100 / 120 / 150 / 180; Basic functions: First, brief description: It is suitable for the installation of high-efficiency propane fire-extinguishing devices in the places where there is no need of fluorine gas tank and stain, and it is not suitable for the installation of high-efficiency propane fire-extinguishing devices, and there is no need for installation and maintenance. It is suitable for the places where there is no need for fluorine gas tank and stain. It is a cabinet type fire extinguishing device that integrates the components of fire extinguishing agent storage container, spraying pipeline, nozzle and valve driving device and is connected with the automatic fire alarm controller to realize automatic control, measurement and fire extinguishing. Since the fire extinguishing agent storage bottle is placed in the cabinet, for small protection areas of different sizes, select single bottle groups with different volumes for protection, which can reduce the floor area; The nozzle adopts multi hole type, which can make the fire extinguishing agent fill the whole protection area quickly and evenly; Like the hanging fire extinguishing device, it has the characteristics of simple construction and installation and small project investment. Second, product application It is widely used in electronic computer room, communication room, data warehouse, power distribution room, generator room, library and archives and other valuable equipment rooms. Third, product maintenance 1. Inspection (1) Daily appearance and pressure indication of the device shall be checked by trained personnel every day. (2) Check the pressure gauge at least once a quarter. If the pointer exceeds the green area or is used, entrust the manufacturer or a fire engineering unit trained and qualified for professional installation to repair it. (3) Weigh and check the fire extinguishing agent storage bottle once a year. If the weight of the storage bottle decreases by more than 5% of the total weight, the storage bottle must be refilled or replaced; Conduct an action test on the solenoid valve of the electromagnetic fire extinguishing device every year, and continue to use it after passing the test. (4) The storage bottle shall be inspected regularly according to the regulations on safety supervision of gas cylinders and other relevant national standards. It can be used only after it is qualified. If there is rust, the storage bottle shall be treated with rust prevention. While checking the storage bottle, conduct hydraulic strength test on all valves as required. 2. Maintenance (1) Fire extinguishing devices must always be in good working condition, and maintenance personnel must be specially trained. Any failure or damage to the fire extinguishing device must be repaired in time and recorded in detail. (2) After the fire-fighting equipment is trained or installed by the entrusted fire-fighting plant, it shall obtain the professional qualification of fire-fighting equipment.